Français English Deutsch Italiano Espanol
... www.chauvin-arnoux.com
ChauvinArnoux Metrix Enerdis PyroControle Manumesure Enerdis, Chauvin Arnoux group Compteurs d'énergie, centrales de mesure, indicateurs, transformateurs de courant... / Power monitors and energy meters, panel meters, current transformers...
Home Page Chauvin Armoux
Measurement instruments  OK
Insulation meters Appareils de mesure électrique Metrix, Enerdis, Pyro-Controle
ENERDIS Homepage
Power Measurement & Control
Mesure Chauvin Arnoux
Homepage T&M
Hand-held and portable instruments
PYRO-CONTROLE Homepage
Temperature Measurement & Control
MANUMESURE Homepage
Repair, testing, calibration and maintenance
measurement calibration
Test and measurement
Test and measurement metrix, chauvin arnoux enerdis
pyro-controle
 Support measurement instruments
mesure électrique
mesure électronique gestion énergie mesure de température
Oscilloscopes Metrix multimètres Metrix panel meters
digital panel meter
temperature sensors
temperature measurement
temperature control power measurement Registered? Sign in!
insulation meters First visit? Register!
insulation testers
earth measurement
electrical power measurementanalog oscilloscopes
power analyzer
power meter
Change language

  electrical network analyzers > electrical network quality analyzer

 
Map three-phase Print
Quality analysis systems for all electrical networks
From measurement capture to data processing, the MAP analyzers measure and analyze all the parameters of HV/MV/LV:
  • RMS voltage and current
  • active, reactive, apparent and distorting power
  • energy values
  • cos phi
  • power factor
  • THD-U and THD-I
  • harmonics up to the 50th order and interharmonics
  • inverse unbalance for voltage and current, etc.


    The MAP models record the data and provide , via the associated software, detailed, comprehensive and continuous analysis of the quality of the electricity supply in line with the applicable standards and particularly NF EN 50160:
  • voltage variations (dips, swells and outages)
  • rapid variations (transients, flicker)


    On the MAP 620, 640, 650-ni and 670-ni models, the additional 20 mA analogue inputs can be used to:
  • monitor physical parameters transmitted by 20 mA transducers
  • carry out status monitoring on elements such as circuit-breaker contacts and protection relays, via suitable couplers
  • trigger waveform capture via a logic channel, using a logic input / 20 mA signal coupler
  • control equipment emitting on-off signals


    Various communication modes are available for remote recovery of the data and detailed analysis of all the parameters recorded:
  • RS232
  • CL port
  • Ethernet port (RJ45)

    The products in the MAP range are available in 2 versions:
  • permanent analyzers (MAP 610 , 620 and 640)
  • non-intrusive analyzers for measurement campaigns (MAP 612-ni, 650-ni and 670-ni)

    2 software products are available for management and analysis:
  • E.Qual-Premium
  • E.Qual-Premium Server
    E.Qual-Premium can be used to generate:
  • the views of the events
  • the views of the transients
  • the views of the trend curves
  • the views of the measurement campaign summaries
  • the reports generated directly in Ms Word® format and, with the E.Qual-Premium Server client-server version:
  • the multi-equipment graphic views
  • the multi-equipment event logs
  • the statistical views
  •  
    Power your analyzers with ENERDIS current transformers:
    CT Class 0.2: JVS range
    Split core CT: TCRO range
     
    Typical applications : Better control the quality of electrical energy
    Ensure the availability of electrical energy
    Optimize the supply contract
    Check specifications according to EN 50160
     
    Demande de devis sur produit du groupe Chauvin Arnoux   Select your products
    To request a price quotation, you need to sign in. Then indicate the desired quantity of products and, if need be, the Quality Assurance services.
    Lastly, add them to your Selection by clicking on OK.
    MAP610 3PH VOLT MONITOR EN50160
    Ref. MAP610-200
      Qty
    MAP610 3PH VOLT MONITOR EN50160-48VDC
    Ref. MAP610-240
      Qty
    MAP610 3PH VOLT MONITOR EN50160-48VDC-690V
    Ref. MAP610-246
      Qty
    MAP610 3PH VOLT MONITOR EN50160-690V
    Ref. MAP610-206
      Qty
    MAP610 3PH VOLT MONITOR TRANSIENT 12-8K
    Ref. MAP610-300
      Qty
    MAP610 3PH VOLT MONITOR TRANSIENT 12-8K-48VDC
    Ref. MAP610-340
      Qty
    MAP610 3PH VOLT MONITOR TRANSIENT 12-8K-690V
    Ref. MAP610-306
      Qty
    MAP610 3PH VOLT MONITOR TRANSIENT12-8K-48VDC-690V
    Ref. MAP610-346
      Qty
    MAP620 3PH NETW MONITOR 48VDC
    Ref. MAP620-040
      Qty
    MAP620 3PH NETW MONITOR 48VDC-690V
    Ref. MAP620-046
      Qty
    MAP620 3PH NETW MONITOR 690V
    Ref. MAP620-006
      Qty
    MAP620 3PH NETW MONITOR ETHERNET
    Ref. MAP620-E00
      Qty
    MAP620 3PH NETW MONITOR ETHERNET-48VDC
    Ref. MAP620-E40
      Qty
    MAP620 3PH NETW MONITOR ETHERNET-48VDC-690V
    Ref. MAP620-E46
      Qty
    MAP620 3PH NETW MONITOR ETHERNET-690V
    Ref. MAP620-E06
      Qty
    MAP620 3PH NETW MONITOR W-O OPTION
    Ref. MAP620-000
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-48VDC
    Ref. MAP640-040
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-48VDC-690V
    Ref. MAP640-046
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-690V
    Ref. MAP640-006
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-ETHERNET
    Ref. MAP640-E00
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-ETHERNET-48VDC
    Ref. MAP640-E40
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-ETHERNET-48VDC-690V
    Ref. MAP640-E46
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-ETHERNET-690V
    Ref. MAP640-E06
      Qty
    MAP640 3PH NETW MONITOR 2MHZ-W-O OPTION
    Ref. MAP640-000
      Qty
    OK
     
    Print this form 
     
     
    Sales literature
      564,4 ko
     
     Read me

     FAQs about Map three-phase
     Division FAQs
     Your contact
     French glossary


    You already possess this instrument, and it requires an operation :
     Maintenance Map three-phase
     Metrological check Map three-phase
     Lab-accredited calibration Map three-phase
     More info (in french)
     Go to Service division